🔥 NBC 2016 Certified
Click to enlarge
Fire Rated Doors & Steel Fire Doors
Yadav Entrance Automation is a fire door manufacturer and fire door supplier in India, building NBC-compliant fire doors and steel fire rated doors that protect lives and property across the country's most critical facilities. Available in 60, 90, 120 and 180-minute fire ratings — from single steel fire doors and double leaf fire doors to emergency exit doors and panic bar fire doors — engineered to EN 1634, IS 3614 and NBC 2016 with full third-party test certification.
Regulatory Compliance Notice
Under NBC 2016 and fire NOC requirements, fire rated doors must be tested and certified per IS 3614 / EN 1634. Non-certified doors will fail fire department inspections. All Yadav fire doors carry third-party test certificates from CBRI / NABL-accredited labs.
| Fire Rating Options | 60 / 90 / 120 / 180 minutes (UL/EN 1634 tested) |
| Max Single Leaf Size | 1,100mm × 2,400mm |
| Smoke Seal | Intumescent + brush seal all four sides |
| Standards | IS 3614, EN 1634, UL 10C, NBC 2016 |
Which Fire Rating Do You Need?
Fire rating specifies how long a door assembly can resist fire without structural failure, flame passage, or excessive heat transmission. NBC 2016 mandates specific ratings for each building use type.
Not sure which rating applies to your building? Our fire safety consultants will advise free of charge →
Every Component Tested. Every Install Certified.
Fire doors are life safety equipment. Our engineering choices reflect that — no cost cutting on hardware, no uncertified substitutions, no shortcuts on installation.
Tested Fire Ratings — Not Self-Declared
Every fire rating we quote is backed by a third-party test certificate from a NABL-accredited laboratory (CBRI Roorkee, CPRI, or equivalent). We provide the actual test report — not a datasheet claim. Copies available on request before order placement.
EN 1125 Panic Bar — Certified Egress
Emergency exit doors carry CE-marked EN 1125 panic bars — the European standard for single-action emergency egress. Push bar activates in one motion, regardless of direction. Latchbolt retracts fully with minimal 150N force. Fire exit signage included.
Four-Sided Smoke Sealing — EN 1634 Compliant
Smoke is responsible for 70%+ of fire deaths. Our intumescent strip expands at 150°C to seal the gap between door and frame. Supplemented by brush seal on the hinge side for positive pressure resistance. Full perimeter coverage — no gaps.
EN 1154 Self-Closing — No Manual Propping
All fire doors are fitted with EN 1154-certified hydraulic overhead closers. Door closes and latches from any open position above 5°. Adjustable closing force (Sizes 2–7). Hold-open electromagnet available — releases on fire alarm activation.
Acoustic Performance — Up to 42 Rw dB
Our soundproof fire door variant combines fire resistance with acoustic attenuation up to 42 Rw dB — sufficient for cinema walls, recording studios, hospital operating theatres, and server room environments. Fire and acoustic rated in a single assembly.
Steel Sub-Frame with Fire-Rated Grout
Our installation method uses a fully welded steel sub-frame anchored with M12 anchor bolts at 300mm centres. Frame cavity is filled with fire-rated intumescent grout. This prevents fire from bypassing the door through the frame-wall junction — a common failure mode.
Types of Fire Doors We Manufacture
Five fire door configurations covering every life-safety and emergency-egress requirement. Searching for a fire door near me? As a pan-India fire door manufacturer and supplier, each is built to order and supplied with third-party test certification to NBC 2016, EN 1634 and IS 3614 — tell us your fire rating, opening size and hardware spec and we engineer to match.
Most Specified
Steel Fire Door
The standard single-leaf steel fire door — a GI/MS clad leaf with a Rockwool or calcium-silicate fire core, tested to 60, 90, 120 or 180-minute fire ratings per EN 1634 and IS 3614. The fire rated steel door of choice for stairwells, service corridors and server rooms.
View details
Wide Openings
Double Leaf Fire Door
A double leaf fire door for main fire exits, lobby access points and equipment passage where a single leaf is too narrow. Equal or unequal leaves up to 2,100mm wide, with an EN 1158 door coordinator ensuring correct closing sequence — rated to 60, 90 or 120 minutes.
View details
Egress
Emergency Exit Door
An emergency exit door engineered for safe escape along NBC 2016 means-of-egress routes, with single-action hardware and fire exit signage. Combines a tested fire rating (60/90/120 min) with reliable one-push opening for stairwells, malls and assembly buildings.
View details
Certified Assembly
Fire Rated Exit Door
A fully tested fire rated exit door supplied as a complete certified assembly — leaf, steel sub-frame, intumescent seals, EN 1154 closer and EN 1935 hinges. Meeting NBC 2016 and EN 1634, it satisfies fire NOC conditions for escape doors in regulated buildings.
View details
Panic Hardware
Panic Bar Fire Door
A panic bar fire door fitted with EN 1125 touch-bar or push-bar hardware for crowded escape routes — releases under 150N in a single motion, even under crowd pressure. The mandated choice for fire exits in cinemas, malls, stadiums and high-occupancy buildings, rated 60/90/120 min.
View detailsWhere Fire Rated Doors Are Mandatory
NBC 2016 and insurance requirements mandate fire rated doors in specific locations within buildings. Our engineers can advise on the correct rating and specification for each location in your facility.
120-minute rated doors with intumescent seals. Essential for FM Global insurance compliance. Integration with suppression system and door hold-opens standard.
90-minute corridor doors with hospital-grade hardware. Hold-open electromagnets release on fire alarm. Smooth operation for gurney and wheelchair passage.
180-minute rated doors for hazardous material storage, solvent rooms, and chemical process areas. GI or SS304 finish for chemical resistance.
90-minute rated stairwell, plant room, and kitchen doors. Concealed closer for aesthetic finish. Master key compatible cylinder for hotel management.
60–90-minute fire exit doors at every stairwell and service corridor. EN 1125 panic bars mandatory for escape routes. Exit signage and emergency lighting integration.
DGCA-compliant fire doors for fuel handling areas, electrical rooms, and cargo bays. SS304 hardware for coastal corrosion resistance.
120-minute fire separation doors between storage compartments for bonded warehouses, flammable goods stores, and cross-docking facilities.
180-minute fire rated doors for transformer bays, cable galleries, and switchgear rooms. Meets IEC 60079 requirements for electrical hazardous area classification.
Full Technical Specifications
Complete engineering data for our fire rated door range. Specifications cover the standard steel fire door with panic bar hardware. Aluminium and acoustic variants differ in door leaf construction.
| Parameter | Specification |
|---|---|
| Fire Rating Options | 60 / 90 / 120 / 180 minutes — third-party tested per EN 1634 / IS 3614 |
| Door Leaf Material | GI sheet (24 gauge outer) / MS sheet with fire-rated core fill |
| Core Infill | Rockwool mineral wool (60/90/120 min) / Calcium silicate board (180 min) |
| Door Leaf Thickness | 45mm (60 min) / 50mm (90 min) / 60mm (120/180 min) |
| Frame Type | Steel sub-frame (2mm pressed steel) with fire-rated intumescent grout fill |
| Frame Fixing | M12 anchor bolts at 300mm centres; fully welded mitre joints |
| Panic Bar Hardware | EN 1125 certified touch bar / push bar — opens with single downward push |
| Door Closer | EN 1154 certified overhead hydraulic closer — Size 2–7 adjustable |
| Lever Handle | EN 179 certified lever handle (non-panic doors) |
| Smoke Seal | Intumescent strip (expands at 150°C) + EPDM brush seal — all four edges |
| Hinge Type | 3 × EN 1935 Gr.14 CE-marked stainless steel hinges per leaf |
| Glazing Option | Fire-rated Georgian wired glass or ceramic glass (up to 30% of leaf area) |
| Maximum Single Leaf Size | 1,100mm wide × 2,400mm high |
| Maximum Double Leaf Size | 2,100mm wide × 2,400mm high (equal or unequal leaves) |
| Sidelight Option | Up to 500mm wide fixed sidelights with fire-rated glass available |
| Acoustic Rating (Soundproof Variant) | Up to 42 Rw dB (weighted sound reduction index) |
| Finish Options | Powder coat (standard) / hot-dip galvanized / SS304 cladding |
| Operating Temperature | -10°C to +50°C ambient (door hardware rated) |
| Standards | IS 3614, EN 1634-1, UL 10C (positive pressure), NBC 2016 |
| Hardware Standards | EN 1125 (panic), EN 1154 (closer), EN 179 (handle), EN 1935 (hinges) |
| Warranty | 5 years structural, lifetime door frame, 2 years hardware |
Fire Door Variant Comparison
| Feature | Fire Exit Door ⭐ Most Specified | Double Door + Panic Bar | Soundproof Acoustic | PUF Insulated Door | |
|---|---|---|---|---|---|
| Fire Rating | 60 / 90 / 120 / 180 min | 60 / 90 / 120 min | 60 / 90 min | 60 / 90 / 120 min | |
| Door Leaf Construction | GI + Rockwool / Cal-Silicate | GI + Rockwool | Steel + Acoustic mineral wool | GI + PUF (polyurethane foam) | — |
| Leaf Thickness | 45 / 50 / 60mm | 50 / 60mm | 60 / 70mm | 45 / 50mm | — |
| Emergency Egress Hardware | EN 1125 panic bar (standard) | EN 1125 panic bar (both leafs) | EN 179 lever handle | EN 179 lever handle | — |
| Acoustic Rating | ~28 Rw dB (inherent) | ~28–32 Rw dB | Up to 42 Rw dB | ~30 Rw dB | — |
| Thermal Insulation | Moderate | Moderate | Moderate | Excellent (U-value ~0.9) | — |
| Best For | Stairwells, service corridors, server rooms | Main fire exits, lobby access points | Hospitals, studios, data centers | Cold rooms, blast freezer entry | — |
Certifications That Matter for Compliance
For fire rated products, certification is not a marketing claim — it is a legal requirement. Every certification we carry has a corresponding third-party test report available for inspection.
3614
Indian Standard for fire check doors — the domestic standard referenced by NBC 2016 and fire NOC conditions. Mandatory for all fire doors in regulated Indian buildings.
1634
European standard for fire resistance of door and shutter assemblies. Accepted by IGBC, LEED India, and multinational occupiers who mandate European testing standards.
10C
Underwriters Laboratories positive pressure fire test. Required by FM Global, Aon, and US insurance underwriters for data centers, warehouses, and industrial facilities.
2016
National Building Code Part 4 (Fire and Life Safety) compliance. Required for building plan approval, fire NOC, and occupancy certificate in all Indian states.
9001
Quality management certification covering the design, manufacturing, hardware specification, installation, and commissioning processes for all fire rated door products.
Related Products
Every Fire Door Quote Includes Test Certificates
When you request a fire door quote from Yadav Entrance Automation, you receive a specification document listing the exact fire rating, test certificate references, and hardware standards — ready to submit to your fire consultant or building plan approvals office.
Third-Party Test Certificates Provided
We provide CBRI / NABL-accredited test report references for every fire rating we supply. No self-declarations.
Fire NOC Documentation Support
Our compliance team assists with fire NOC submission documentation, drawing packages, and technical data sheets required by local fire departments.
Annual Inspection & AMC Available
Fire doors require annual maintenance inspection per NBC 2016. Our AMC includes closer calibration, seal inspection, and a compliance certificate.
Choosing fire-rated doors: what actually decides the specification
A fire door is a tested door assembly that resists fire for a stated period. The right one is decided by the opening and how it is used, not by the catalogue. These are the things worth settling before anyone quotes.
What to measure
- Clear opening width and height — the daylight opening the vehicle or person passes through, not the hole in the wall.
- Headroom above the opening — decides which products are possible at all.
- Side-room, both sides — guides, tracks and motors live here, and it is rarely equal on both sides.
- Power at the position — 230V single-phase or 415V three-phase, 50 Hz.
- Cycles per shift — the most under-specified figure on a typical enquiry.
- Environment — temperature, dust, washdown, coastal air or a hygiene requirement.
The full fire rated doors range
- Steel Fire Door — The standard single-leaf steel fire door — a GI/MS clad leaf with a Rockwool or calcium-silicate fire core, tested to 60, 90, 120 or 180-minute fire ratings per EN 1634 and IS 3614.
- Double Leaf Fire Door — A double leaf fire door for main fire exits, lobby access points and equipment passage where a single leaf is too narrow.
- Emergency Exit Door — An emergency exit door engineered for safe escape along NBC 2016 means-of-egress routes, with single-action hardware and fire exit signage.
- Fire Rated Exit Door — A fully tested fire rated exit door supplied as a complete certified assembly — leaf, steel sub-frame, intumescent seals, EN 1154 closer and EN 1935 hinges.
- Panic Bar Fire Door — A panic bar fire door fitted with EN 1125 touch-bar or push-bar hardware for crowded escape routes — releases under 150N in a single motion, even under crowd pressure.
Where fire-rated doors are typically installed
We build fire-rated doors for escape routes, plant rooms, stairwells and compartment walls.
Sectors we supply
- Warehousing and logistics — distribution centres, 3PL facilities and dispatch docks.
- Cold chain — cold stores, freezer rooms and temperature-controlled dispatch.
- Automotive and engineering — component plants, press shops and assembly lines.
- Pharmaceutical and clean manufacturing — controlled and hygiene-critical areas.
- Infrastructure and construction — plant perimeters, site structures and civil scopes.
- Commercial and institutional — offices, campuses, hospitals and parking facilities.
What drives the cost
We quote per project rather than publishing prices. The figure moves with the rating required, the leaf size, the hardware schedule and the vision-panel detail. Send the measurements above and an engineer returns a drawing and a written quotation. Talk to an engineer →
Standards, materials and what we certify
- ISO 9001 — our quality management system is certified to it.
- CE marking on applicable products — a manufacturer's declaration of conformity, not a quality grade.
- IS 2062 structural steel for fabrication, gates and structures.
- IS 6248 for metal rolling shutters.
- EN 1634 as the reference for fire-resistance testing.
- Make in India and GST registered — relevant to government and PSU procurement.
- 230V single-phase / 415V three-phase, 50 Hz — standard Indian industrial mains.
Reference sources: European Commission, CE marking · Bureau of Indian Standards
From enquiry to handover
- Enquiry. Opening sizes, site location and application. An engineer picks it up.
- Site survey. We measure the clear opening, headroom, side-room and power position.
- Drawing and quotation. Equipment, safety schedule, electrical requirement and a written delivery date.
- Manufacture at Neemrana. Built to the approved drawing and the measured opening.
- Installation and commissioning. Fitted and tested by our own team through full travel with safety devices live.
- Handover, spares and AMC. Operating instructions on site, then service through the nearest team.
Explore the full product range, the sectors we serve, our delivered installations, or the areas we cover.
Fire-Rated Doors — frequently asked questions
Who manufactures fire-rated doors in India?
Yadav Entrance Automation Pvt. Ltd. manufactures fire-rated doors in India, at our plant at Neemrana, Rajasthan on the Delhi-Jaipur NH-48 corridor. We have been building entrance automation equipment since 2011, with more than 500 installations across over 50 cities. Equipment is made to the measured opening rather than to a catalogue size, then installed and commissioned by our own engineers.
What is a fire door?
A fire door is a tested door assembly that resists fire for a stated period. It is specified against the opening it serves and the way that opening is used, so two openings of the same width can need different equipment. We build fire-rated doors for escape routes, plant rooms, stairwells and compartment walls.
What does a fire door cost?
We quote per project rather than publishing a price, because the figure moves with the rating required, the leaf size, the hardware schedule and the vision-panel detail. Send the opening dimensions, the site location and how the opening is used, and an engineer will come back with a drawing and a written quotation. That is faster than a list price that would need revising once the site is measured.
Do you supply fire-rated doors near me?
We install and service across North and West India, with the plant at Neemrana and teams in Delhi NCR and Gujarat. Installations to date cover more than 50 cities, concentrated in the Delhi-Jaipur corridor, Haryana, Rajasthan and Gujarat. Tell us the site location with your enquiry and we will confirm coverage before quoting.
Can fire-rated doors be motorised or automated?
Yes, where the product supports it. Motorised operation is specified against the weight being moved and the number of cycles per day, not simply added on. The drive, the control panel and the safety devices are listed on the technical drawing you approve before manufacture, so nothing about the automation is a surprise on site.
What power supply is needed?
Standard Indian industrial mains: 230V single-phase or 415V three-phase at 50 Hz. Which one applies depends on the product, the size of the opening and the duty cycle. The requirement is confirmed on the approved drawing so your electrical contractor can position the supply and isolator before delivery.
What measurements do you need to quote for fire-rated doors?
Clear opening width and height first — the daylight opening, not the wall opening. Then the headroom above the opening and the free side-room each side. Add the power available at the position, how many openings, and roughly how often each is used in a shift. Those figures let an engineer rule out the wrong products before visiting.
Do you handle installation, or only supply?
We manufacture, install and commission with our own team, and we do not sub-contract installation of our own equipment. How well a unit is fitted to its opening decides how long it lasts, so it is not work we hand off. Handover includes operating instructions on site.
Do you provide service, spares and AMC?
Yes. We supply genuine spares and offer Annual Maintenance Contracts for the equipment we manufacture. On high-cycle equipment maintenance matters more than most buyers expect, because wear tracks cycles rather than calendar age. Tell us the site and the equipment and we will route it to the nearest service team.
Which standards and certifications apply?
Our manufacturing is certified to ISO 9001 and applicable products are CE marked. Structural steelwork commonly references IS 2062 and rolling shutters IS 6248, both published by the Bureau of Indian Standards; fire-resistance testing is commonly referenced to EN 1634. If your specification names a standard, send the clause with the enquiry so it is written into the drawing.
Can you make fire-rated doors to a non-standard size?
Yes, and most industrial openings are non-standard. Equipment is built to the measured opening rather than to a catalogue size. We take the clear width, clear height, headroom and side-room on site, then confirm the achievable size on the drawing before manufacture begins.
How long does manufacture and delivery take?
It depends on the product and whether the opening is standard or bespoke, and it moves with material availability and the current order book. Rather than quote a general figure that may not hold, we confirm a delivery date in writing with the quotation.
Do you work with contractors, consultants and PSUs?
Yes. We supply end users directly and also work as a vendor to main contractors, PMCs and design consultants. We are GST registered and manufacture under Make in India, which matters for government and PSU procurement. For tendered work we can provide drawings, product data and the compliance documentation the specification calls for.
What safety devices are included?
For powered equipment, typically safety photocells across the opening, a safety edge where applicable, limit switches at both travel ends, and a manual release for use during a power cut. Vehicle equipment can add loop detectors. The exact schedule is listed on the drawing you approve, so check that rather than assuming a standard set.
How do I get a quote for fire-rated doors?
Use the enquiry form on this page and the details reach our team directly, or call and send a WhatsApp message on +91 95492 20707, or email sales@yadaventranceautomation.com. If you already hold drawings or a specification, say so and an engineer will respond rather than a generic reply.