+91 98710 36706 info@yadavautomation.com New Delhi · Mumbai · Pune · Ahmedabad
Home Products About Case Studies Blog
Request Quote WhatsApp Us
🔥 Fire Ratings Available:
⏱ 60 Minutes ⏱ 90 Minutes ⏱ 120 Minutes ⏱ 180 Minutes
NBC 2016 · IS 3614 · EN 1634 Certified
Fire Rated Doors & Emergency Exit Solutions Request Quote
🔥 Fire Rated Doors

Fire Rated Doors & Emergency Exit Solutions

★★★★★ 4.9 / 5 (850+ facility installations)

NBC-compliant fire rated doors protecting lives and property across India's most critical facilities. Available in 60, 90, 120, and 180-minute fire ratings — engineered to EN 1634, IS 3614 standards with full third-party test certification.

⚠️

Regulatory Compliance Notice

Under NBC 2016 and fire NOC requirements, fire rated doors must be tested and certified per IS 3614 / EN 1634. Non-certified doors will fail fire department inspections. All Yadav fire doors carry third-party test certificates from CBRI / NABL-accredited labs.

Key Highlights
Fire ratings: 60 / 90 / 120 / 180 minutes — NBC 2016 compliant
Panic bar hardware for emergency egress — EN 1125 certified
Smoke sealing on all four sides — intumescent + brush seal
Self-closing mechanism — EN 1154 certified hydraulic overhead closer
Acoustic performance: up to 42 dB (soundproof variant)
Available as single leaf, double leaf, with sidelights and fanlights
Select Variant
Fire Exit Door
Double Door + Panic Bar
PUF Door
Aluminium Fire Door
M.S. Fire Door
Steel Door
Office Door
Fire Rated Shutter
Soundproof Acoustic
Quick Specifications
Fire Rating Options60 / 90 / 120 / 180 minutes (UL/EN 1634 tested)
Max Single Leaf Size1,100mm × 2,400mm
Smoke SealIntumescent + brush seal all four sides
StandardsIS 3614, EN 1634, UL 10C, NBC 2016
5 yr structural warranty Third-party test certified Pan-India installation
Understanding Fire Ratings

Which Fire Rating Do You Need?

Fire rating specifies how long a door assembly can resist fire without structural failure, flame passage, or excessive heat transmission. NBC 2016 mandates specific ratings for each building use type.

60 MIN
60-Minute Rating

Suitable for office buildings, retail premises, and stairwell enclosures in low-rise commercial buildings. Minimum requirement for most fire NOC applications.

90 MIN
90-Minute Rating

Required for hotels, residential complexes above 15m height, and multi-tenanted commercial buildings. Standard for most hospital and healthcare facilities.

120 MIN
120-Minute Rating

Specified for data centers, high-rise buildings above 30m, warehousing hazardous materials, and chemical process plants. Required by most enterprise insurance policies.

180 MIN
180-Minute Rating

Maximum rating for power plants, petrochemical facilities, LPG handling areas, airport fuel farms, and critical national infrastructure. Tested under positive pressure conditions (UL 10C).

Not sure which rating applies to your building? Our fire safety consultants will advise free of charge →

Engineering for Life Safety

Every Component Tested. Every Install Certified.

Fire doors are life safety equipment. Our engineering choices reflect that — no cost cutting on hardware, no uncertified substitutions, no shortcuts on installation.

🔥

Tested Fire Ratings — Not Self-Declared

Every fire rating we quote is backed by a third-party test certificate from a NABL-accredited laboratory (CBRI Roorkee, CPRI, or equivalent). We provide the actual test report — not a datasheet claim. Copies available on request before order placement.

🚪

EN 1125 Panic Bar — Certified Egress

Emergency exit doors carry CE-marked EN 1125 panic bars — the European standard for single-action emergency egress. Push bar activates in one motion, regardless of direction. Latchbolt retracts fully with minimal 150N force. Fire exit signage included.

💨

Four-Sided Smoke Sealing — EN 1634 Compliant

Smoke is responsible for 70%+ of fire deaths. Our intumescent strip expands at 150°C to seal the gap between door and frame. Supplemented by brush seal on the hinge side for positive pressure resistance. Full perimeter coverage — no gaps.

⚙️

EN 1154 Self-Closing — No Manual Propping

All fire doors are fitted with EN 1154-certified hydraulic overhead closers. Door closes and latches from any open position above 5°. Adjustable closing force (Sizes 2–7). Hold-open electromagnet available — releases on fire alarm activation.

🔊

Acoustic Performance — Up to 42 Rw dB

Our soundproof fire door variant combines fire resistance with acoustic attenuation up to 42 Rw dB — sufficient for cinema walls, recording studios, hospital operating theatres, and server room environments. Fire and acoustic rated in a single assembly.

🏗️

Steel Sub-Frame with Fire-Rated Grout

Our installation method uses a fully welded steel sub-frame anchored with M12 anchor bolts at 300mm centres. Frame cavity is filled with fire-rated intumescent grout. This prevents fire from bypassing the door through the frame-wall junction — a common failure mode.

Technical Data

Full Technical Specifications

Complete engineering data for our fire rated door range. Specifications cover the standard steel fire door with panic bar hardware. Aluminium and acoustic variants differ in door leaf construction.

Parameter Specification
Fire Rating Options60 / 90 / 120 / 180 minutes — third-party tested per EN 1634 / IS 3614
Door Leaf MaterialGI sheet (24 gauge outer) / MS sheet with fire-rated core fill
Core InfillRockwool mineral wool (60/90/120 min) / Calcium silicate board (180 min)
Door Leaf Thickness45mm (60 min) / 50mm (90 min) / 60mm (120/180 min)
Frame TypeSteel sub-frame (2mm pressed steel) with fire-rated intumescent grout fill
Frame FixingM12 anchor bolts at 300mm centres; fully welded mitre joints
Panic Bar HardwareEN 1125 certified touch bar / push bar — opens with single downward push
Door CloserEN 1154 certified overhead hydraulic closer — Size 2–7 adjustable
Lever HandleEN 179 certified lever handle (non-panic doors)
Smoke SealIntumescent strip (expands at 150°C) + EPDM brush seal — all four edges
Hinge Type3 × EN 1935 Gr.14 CE-marked stainless steel hinges per leaf
Glazing OptionFire-rated Georgian wired glass or ceramic glass (up to 30% of leaf area)
Maximum Single Leaf Size1,100mm wide × 2,400mm high
Maximum Double Leaf Size2,100mm wide × 2,400mm high (equal or unequal leaves)
Sidelight OptionUp to 500mm wide fixed sidelights with fire-rated glass available
Acoustic Rating (Soundproof Variant)Up to 42 Rw dB (weighted sound reduction index)
Finish OptionsPowder coat (standard) / hot-dip galvanized / SS304 cladding
Operating Temperature-10°C to +50°C ambient (door hardware rated)
StandardsIS 3614, EN 1634-1, UL 10C (positive pressure), NBC 2016
Hardware StandardsEN 1125 (panic), EN 1154 (closer), EN 179 (handle), EN 1935 (hinges)
Warranty5 years structural, lifetime door frame, 2 years hardware
Download Full Spec Sheet + Test Cert. Summary Request Custom Specifications
Door Assembly

Fire Door — Component Breakdown

Understanding the fire door assembly helps ensure correct specification and installation. Each component must be from the tested and certified assembly — substituting uncertified components invalidates the fire rating.

Fire rated door assembly diagram
1
2
3
4
5
6
7
8
9
10
11
12
Fire Door Component Guide
1
Overhead Door Closer (EN 1154)

CE-marked hydraulic overhead closer. Ensures door closes and latches from any open angle. Size 3–5 standard; adjustable closing speed and latching action.

2
Steel Sub-Frame

2mm pressed steel frame with fully welded mitre joints. Anchored to wall structure with M12 bolts at 300mm centres. Frame cavity filled with intumescent fire-rated grout.

3
EN 1935 Grade 14 Hinges

Three CE-marked stainless steel hinges per leaf. Butt hinge with ball-bearing pivot. Must remain part of the tested assembly — uncertified replacement invalidates the rating.

4
EN 1125 Panic Bar

Touch bar or full-width push bar with single-action release. Opens with 150N max force. Anti-panic feature: bar cannot be locked from inside when occupied.

5
Fire-Rated Door Leaf

Sandwich construction: 24-gauge GI outer skins with Rockwool (60/90/120 min) or calcium silicate board (180 min) core. Overall thickness 45–60mm.

6
EN 179 Lever Handle

CE-marked lever handle set for non-panic fire doors. Spring-loaded return. Stainless steel or powder coat finish. Back plate integrated to prevent heat transfer.

7
Fire-Rated Vision Panel

Georgian wired glass or ceramic fire-rated glass in steel glazing bead. Max 30% of leaf area. EN 1634-compliant — same fire resistance as the door leaf.

8
Bottom Door Seal (EPDM + Intumescent)

Automatic drop seal or fixed EPDM brush seal at threshold. Intumescent strip embedded in bottom edge expands at 150°C to seal gap under positive pressure.

9
Perimeter Intumescent Strip

3mm × 10mm intumescent strip in all four rebate faces. Expands 3–4× at 150°C — seals smoke and flame path at door/frame interface. Critical life-safety component.

10
Mortise Lock Body

Fire-rated mortise lock with anti-thrust latch. Stainless steel bolt and latch. Compatible with cylinder (keyed) or thumb-turn operation. Electric strike option for access control.

11
Cylinder Lock

5-pin tumbler cylinder lock. Master-keyed system available for hotel or hospital installations. Anti-drill, anti-pick protection.

12
Door Coordinator (Double Leaf)

For double leaf doors, an EN 1158-certified door coordinator ensures the inactive leaf always closes before the active leaf — preventing seal bypass.

Critical Application Areas

Where Fire Rated Doors Are Mandatory

NBC 2016 and insurance requirements mandate fire rated doors in specific locations within buildings. Our engineers can advise on the correct rating and specification for each location in your facility.

🖥️
Server Rooms & Data Centers

120-minute rated doors with intumescent seals. Essential for FM Global insurance compliance. Integration with suppression system and door hold-opens standard.

🏥
Hospitals & Healthcare

90-minute corridor doors with hospital-grade hardware. Hold-open electromagnets release on fire alarm. Smooth operation for gurney and wheelchair passage.

⚗️
Chemical & Pharma Plants

180-minute rated doors for hazardous material storage, solvent rooms, and chemical process areas. GI or SS304 finish for chemical resistance.

🏨
Hotels & Hospitality

90-minute rated stairwell, plant room, and kitchen doors. Concealed closer for aesthetic finish. Master key compatible cylinder for hotel management.

🏢
Commercial Complexes & Malls

60–90-minute fire exit doors at every stairwell and service corridor. EN 1125 panic bars mandatory for escape routes. Exit signage and emergency lighting integration.

✈️
Airports & Aviation

DGCA-compliant fire doors for fuel handling areas, electrical rooms, and cargo bays. SS304 hardware for coastal corrosion resistance.

📦
Warehouses — Flammable Goods

120-minute fire separation doors between storage compartments for bonded warehouses, flammable goods stores, and cross-docking facilities.

Power Plants & Substations

180-minute fire rated doors for transformer bays, cable galleries, and switchgear rooms. Meets IEC 60079 requirements for electrical hazardous area classification.

Configuration Guide

Fire Door Variant Comparison

All variants carry third-party fire test certification. Variant selection is based on application, budget, aesthetic requirement, and the specific hardware configuration mandated by your fire NOC.

Feature Fire Exit Door ⭐ Most Specified Double Door + Panic Bar Soundproof Acoustic PUF Insulated Door
Fire Rating 60 / 90 / 120 min 60 / 90 min 60 / 90 / 120 min
Door Leaf Construction GI + Rockwool Steel + Acoustic mineral wool GI + PUF (polyurethane foam)
Leaf Thickness 50 / 60mm 60 / 70mm 45 / 50mm
Emergency Egress Hardware EN 1125 panic bar (both leafs) EN 179 lever handle EN 179 lever handle
Acoustic Rating ~28–32 Rw dB Up to 42 Rw dB ~30 Rw dB
Thermal Insulation Moderate Moderate Excellent (U-value ~0.9)
Best For Main fire exits, lobby access points Hospitals, studios, data centers Cold rooms, blast freezer entry
Starting Price ₹42,000 – ₹80,000 per set ₹55,000 – ₹90,000 per leaf ₹22,000 – ₹45,000 per leaf

* Prices include door, frame, hardware, and fitting. Vary by rating, size, and site conditions. Get a formal itemized quote →

Certifications & Standards

Certifications That Matter for Compliance

For fire rated products, certification is not a marketing claim — it is a legal requirement. Every certification we carry has a corresponding third-party test report available for inspection.

IS 3614:2021

Indian Standard for fire check doors — the domestic standard referenced by NBC 2016 and fire NOC conditions. Mandatory for all fire doors in regulated Indian buildings.

EN 1634-1

European standard for fire resistance of door and shutter assemblies. Accepted by IGBC, LEED India, and multinational occupiers who mandate European testing standards.

UL 10C

Underwriters Laboratories positive pressure fire test. Required by FM Global, Aon, and US insurance underwriters for data centers, warehouses, and industrial facilities.

NBC 2016 Compliant

National Building Code Part 4 (Fire and Life Safety) compliance. Required for building plan approval, fire NOC, and occupancy certificate in all Indian states.

ISO 9001:2015

Quality management certification covering the design, manufacturing, hardware specification, installation, and commissioning processes for all fire rated door products.

Also Consider

Related Products

Get a Compliance Quote

Fire Door Quotes Include Test Certificates — Not Just Prices

When you request a fire door quote from Yadav Automation, you receive a specification document listing the exact fire rating, test certificate references, and hardware standards — ready to submit to your fire consultant or building plan approvals office.

🔥

Third-Party Test Certificates Provided

We provide CBRI / NABL-accredited test report references for every fire rating we supply. No self-declarations.

📋

Fire NOC Documentation Support

Our compliance team assists with fire NOC submission documentation, drawing packages, and technical data sheets required by local fire departments.

🔧

Annual Inspection & AMC Available

Fire doors require annual maintenance inspection per NBC 2016. Our AMC includes closer calibration, seal inspection, and a compliance certificate.

Request Fire Door Quote

Specification document + compliance summary within 24 hours. Free site survey included.

Response with test certificate references and specification within 24 hours. No spam, no data sharing.

Chat on WhatsApp