🔥 NBC 2016 Certified
Click to enlarge
NBC-compliant fire rated doors protecting lives and property across India's most critical facilities. Available in 60, 90, 120, and 180-minute fire ratings — engineered to EN 1634, IS 3614 standards with full third-party test certification.
Under NBC 2016 and fire NOC requirements, fire rated doors must be tested and certified per IS 3614 / EN 1634. Non-certified doors will fail fire department inspections. All Yadav fire doors carry third-party test certificates from CBRI / NABL-accredited labs.
| Fire Rating Options | 60 / 90 / 120 / 180 minutes (UL/EN 1634 tested) |
| Max Single Leaf Size | 1,100mm × 2,400mm |
| Smoke Seal | Intumescent + brush seal all four sides |
| Standards | IS 3614, EN 1634, UL 10C, NBC 2016 |
Fire rating specifies how long a door assembly can resist fire without structural failure, flame passage, or excessive heat transmission. NBC 2016 mandates specific ratings for each building use type.
Not sure which rating applies to your building? Our fire safety consultants will advise free of charge →
Fire doors are life safety equipment. Our engineering choices reflect that — no cost cutting on hardware, no uncertified substitutions, no shortcuts on installation.
Every fire rating we quote is backed by a third-party test certificate from a NABL-accredited laboratory (CBRI Roorkee, CPRI, or equivalent). We provide the actual test report — not a datasheet claim. Copies available on request before order placement.
Emergency exit doors carry CE-marked EN 1125 panic bars — the European standard for single-action emergency egress. Push bar activates in one motion, regardless of direction. Latchbolt retracts fully with minimal 150N force. Fire exit signage included.
Smoke is responsible for 70%+ of fire deaths. Our intumescent strip expands at 150°C to seal the gap between door and frame. Supplemented by brush seal on the hinge side for positive pressure resistance. Full perimeter coverage — no gaps.
All fire doors are fitted with EN 1154-certified hydraulic overhead closers. Door closes and latches from any open position above 5°. Adjustable closing force (Sizes 2–7). Hold-open electromagnet available — releases on fire alarm activation.
Our soundproof fire door variant combines fire resistance with acoustic attenuation up to 42 Rw dB — sufficient for cinema walls, recording studios, hospital operating theatres, and server room environments. Fire and acoustic rated in a single assembly.
Our installation method uses a fully welded steel sub-frame anchored with M12 anchor bolts at 300mm centres. Frame cavity is filled with fire-rated intumescent grout. This prevents fire from bypassing the door through the frame-wall junction — a common failure mode.
Complete engineering data for our fire rated door range. Specifications cover the standard steel fire door with panic bar hardware. Aluminium and acoustic variants differ in door leaf construction.
| Parameter | Specification |
|---|---|
| Fire Rating Options | 60 / 90 / 120 / 180 minutes — third-party tested per EN 1634 / IS 3614 |
| Door Leaf Material | GI sheet (24 gauge outer) / MS sheet with fire-rated core fill |
| Core Infill | Rockwool mineral wool (60/90/120 min) / Calcium silicate board (180 min) |
| Door Leaf Thickness | 45mm (60 min) / 50mm (90 min) / 60mm (120/180 min) |
| Frame Type | Steel sub-frame (2mm pressed steel) with fire-rated intumescent grout fill |
| Frame Fixing | M12 anchor bolts at 300mm centres; fully welded mitre joints |
| Panic Bar Hardware | EN 1125 certified touch bar / push bar — opens with single downward push |
| Door Closer | EN 1154 certified overhead hydraulic closer — Size 2–7 adjustable |
| Lever Handle | EN 179 certified lever handle (non-panic doors) |
| Smoke Seal | Intumescent strip (expands at 150°C) + EPDM brush seal — all four edges |
| Hinge Type | 3 × EN 1935 Gr.14 CE-marked stainless steel hinges per leaf |
| Glazing Option | Fire-rated Georgian wired glass or ceramic glass (up to 30% of leaf area) |
| Maximum Single Leaf Size | 1,100mm wide × 2,400mm high |
| Maximum Double Leaf Size | 2,100mm wide × 2,400mm high (equal or unequal leaves) |
| Sidelight Option | Up to 500mm wide fixed sidelights with fire-rated glass available |
| Acoustic Rating (Soundproof Variant) | Up to 42 Rw dB (weighted sound reduction index) |
| Finish Options | Powder coat (standard) / hot-dip galvanized / SS304 cladding |
| Operating Temperature | -10°C to +50°C ambient (door hardware rated) |
| Standards | IS 3614, EN 1634-1, UL 10C (positive pressure), NBC 2016 |
| Hardware Standards | EN 1125 (panic), EN 1154 (closer), EN 179 (handle), EN 1935 (hinges) |
| Warranty | 5 years structural, lifetime door frame, 2 years hardware |
Understanding the fire door assembly helps ensure correct specification and installation. Each component must be from the tested and certified assembly — substituting uncertified components invalidates the fire rating.
CE-marked hydraulic overhead closer. Ensures door closes and latches from any open angle. Size 3–5 standard; adjustable closing speed and latching action.
2mm pressed steel frame with fully welded mitre joints. Anchored to wall structure with M12 bolts at 300mm centres. Frame cavity filled with intumescent fire-rated grout.
Three CE-marked stainless steel hinges per leaf. Butt hinge with ball-bearing pivot. Must remain part of the tested assembly — uncertified replacement invalidates the rating.
Touch bar or full-width push bar with single-action release. Opens with 150N max force. Anti-panic feature: bar cannot be locked from inside when occupied.
Sandwich construction: 24-gauge GI outer skins with Rockwool (60/90/120 min) or calcium silicate board (180 min) core. Overall thickness 45–60mm.
CE-marked lever handle set for non-panic fire doors. Spring-loaded return. Stainless steel or powder coat finish. Back plate integrated to prevent heat transfer.
Georgian wired glass or ceramic fire-rated glass in steel glazing bead. Max 30% of leaf area. EN 1634-compliant — same fire resistance as the door leaf.
Automatic drop seal or fixed EPDM brush seal at threshold. Intumescent strip embedded in bottom edge expands at 150°C to seal gap under positive pressure.
3mm × 10mm intumescent strip in all four rebate faces. Expands 3–4× at 150°C — seals smoke and flame path at door/frame interface. Critical life-safety component.
Fire-rated mortise lock with anti-thrust latch. Stainless steel bolt and latch. Compatible with cylinder (keyed) or thumb-turn operation. Electric strike option for access control.
5-pin tumbler cylinder lock. Master-keyed system available for hotel or hospital installations. Anti-drill, anti-pick protection.
For double leaf doors, an EN 1158-certified door coordinator ensures the inactive leaf always closes before the active leaf — preventing seal bypass.
NBC 2016 and insurance requirements mandate fire rated doors in specific locations within buildings. Our engineers can advise on the correct rating and specification for each location in your facility.
120-minute rated doors with intumescent seals. Essential for FM Global insurance compliance. Integration with suppression system and door hold-opens standard.
90-minute corridor doors with hospital-grade hardware. Hold-open electromagnets release on fire alarm. Smooth operation for gurney and wheelchair passage.
180-minute rated doors for hazardous material storage, solvent rooms, and chemical process areas. GI or SS304 finish for chemical resistance.
90-minute rated stairwell, plant room, and kitchen doors. Concealed closer for aesthetic finish. Master key compatible cylinder for hotel management.
60–90-minute fire exit doors at every stairwell and service corridor. EN 1125 panic bars mandatory for escape routes. Exit signage and emergency lighting integration.
DGCA-compliant fire doors for fuel handling areas, electrical rooms, and cargo bays. SS304 hardware for coastal corrosion resistance.
120-minute fire separation doors between storage compartments for bonded warehouses, flammable goods stores, and cross-docking facilities.
180-minute fire rated doors for transformer bays, cable galleries, and switchgear rooms. Meets IEC 60079 requirements for electrical hazardous area classification.
All variants carry third-party fire test certification. Variant selection is based on application, budget, aesthetic requirement, and the specific hardware configuration mandated by your fire NOC.
| Feature | Fire Exit Door ⭐ Most Specified | Double Door + Panic Bar | Soundproof Acoustic | PUF Insulated Door |
|---|---|---|---|---|
| Fire Rating | 60 / 90 / 120 / 180 min | 60 / 90 / 120 min | 60 / 90 min | 60 / 90 / 120 min |
| Door Leaf Construction | GI + Rockwool / Cal-Silicate | GI + Rockwool | Steel + Acoustic mineral wool | GI + PUF (polyurethane foam) |
| Leaf Thickness | 45 / 50 / 60mm | 50 / 60mm | 60 / 70mm | 45 / 50mm |
| Emergency Egress Hardware | EN 1125 panic bar (standard) | EN 1125 panic bar (both leafs) | EN 179 lever handle | EN 179 lever handle |
| Acoustic Rating | ~28 Rw dB (inherent) | ~28–32 Rw dB | Up to 42 Rw dB | ~30 Rw dB |
| Thermal Insulation | Moderate | Moderate | Moderate | Excellent (U-value ~0.9) |
| Best For | Stairwells, service corridors, server rooms | Main fire exits, lobby access points | Hospitals, studios, data centers | Cold rooms, blast freezer entry |
| Starting Price | ₹18,000 – ₹35,000 per leaf | ₹42,000 – ₹80,000 per set | ₹55,000 – ₹90,000 per leaf | ₹22,000 – ₹45,000 per leaf |
* Prices include door, frame, hardware, and fitting. Vary by rating, size, and site conditions. Get a formal itemized quote →
For fire rated products, certification is not a marketing claim — it is a legal requirement. Every certification we carry has a corresponding third-party test report available for inspection.
Indian Standard for fire check doors — the domestic standard referenced by NBC 2016 and fire NOC conditions. Mandatory for all fire doors in regulated Indian buildings.
European standard for fire resistance of door and shutter assemblies. Accepted by IGBC, LEED India, and multinational occupiers who mandate European testing standards.
Underwriters Laboratories positive pressure fire test. Required by FM Global, Aon, and US insurance underwriters for data centers, warehouses, and industrial facilities.
National Building Code Part 4 (Fire and Life Safety) compliance. Required for building plan approval, fire NOC, and occupancy certificate in all Indian states.
Quality management certification covering the design, manufacturing, hardware specification, installation, and commissioning processes for all fire rated door products.
When you request a fire door quote from Yadav Automation, you receive a specification document listing the exact fire rating, test certificate references, and hardware standards — ready to submit to your fire consultant or building plan approvals office.
We provide CBRI / NABL-accredited test report references for every fire rating we supply. No self-declarations.
Our compliance team assists with fire NOC submission documentation, drawing packages, and technical data sheets required by local fire departments.
Fire doors require annual maintenance inspection per NBC 2016. Our AMC includes closer calibration, seal inspection, and a compliance certificate.
Specification document + compliance summary within 24 hours. Free site survey included.
Response with test certificate references and specification within 24 hours. No spam, no data sharing.